This job view page is being replaced by Spyglass soon. Check out the new job view.
ResultFAILURE
Tests 6 failed / 190 succeeded
Started2020-01-10 18:41
Elapsed4h11m
Revision
Buildergke-prow-default-pool-cf4891d4-j0wd
links{u'resultstore': {u'url': u'https://source.cloud.google.com/results/invocations/29b830bd-c04f-450a-b7f9-77074851416d/targets/test'}}
podb62d16d2-33d8-11ea-a4dc-8213d962824c
resultstorehttps://source.cloud.google.com/results/invocations/29b830bd-c04f-450a-b7f9-77074851416d/targets/test
infra-commit592006eca
job-versionv1.18.0-alpha.1.578+66262e351dad61
master_os_imagecos-77-12371-89-0
node_os_imagecos-77-12371-89-0
podb62d16d2-33d8-11ea-a4dc-8213d962824c
repogithub.com/containerd/cri
repo-commit83a9d2460c5fdd4843141386e3b3b462a137f51c
repos{u'github.com/containerd/cri': u'master'}
revisionv1.18.0-alpha.1.578+66262e351dad61

Test Failures


Kubernetes e2e suite [sig-storage] CSI Volumes [Driver: pd.csi.storage.gke.io][Serial] [Testpattern: Dynamic PV (block volmode)(allowExpansion)] volume-expand Verify if offline PVC expansion works 6m31s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sCSI\sVolumes\s\[Driver\:\spd\.csi\.storage\.gke\.io\]\[Serial\]\s\[Testpattern\:\sDynamic\sPV\s\(block\svolmode\)\(allowExpansion\)\]\svolume\-expand\sVerify\sif\soffline\sPVC\sexpansion\sworks$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:161
Jan 10 20:40:13.396: while recreating pod for resizing
Unexpected error:
    <*errors.errorString | 0xc0032f1a00>: {
        s: "pod \"security-context-dbc2b28f-091c-4fc9-95e2-ab7eea77674c\" is not Running: timed out waiting for the condition",
    }
    pod "security-context-dbc2b28f-091c-4fc9-95e2-ab7eea77674c" is not Running: timed out waiting for the condition
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:209
				
				Click to see stdout/stderrfrom junit_01.xml

Find for mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] CSI Volumes [Driver: pd.csi.storage.gke.io][Serial] [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow] should access to two volumes with the same volume mode and retain data across pod recreation on different node 1m13s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sCSI\sVolumes\s\[Driver\:\spd\.csi\.storage\.gke\.io\]\[Serial\]\s\[Testpattern\:\sDynamic\sPV\s\(block\svolmode\)\]\smultiVolume\s\[Slow\]\sshould\saccess\sto\stwo\svolumes\swith\sthe\ssame\svolume\smode\sand\sretain\sdata\sacross\spod\srecreation\son\sdifferent\snode$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:159
Jan 10 19:55:37.627: waiting for csi driver node registration on: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/drivers/csi.go:463
				
				Click to see stdout/stderrfrom junit_01.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] CSI Volumes [Driver: pd.csi.storage.gke.io][Serial] [Testpattern: Dynamic PV (default fs)] subPath should support existing directory 1m3s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sCSI\sVolumes\s\[Driver\:\spd\.csi\.storage\.gke\.io\]\[Serial\]\s\[Testpattern\:\sDynamic\sPV\s\(default\sfs\)\]\ssubPath\sshould\ssupport\sexisting\sdirectory$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:202
Jan 10 21:17:32.624: waiting for csi driver node registration on: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/drivers/csi.go:463
				
				Click to see stdout/stderrfrom junit_01.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] CSI Volumes [Driver: pd.csi.storage.gke.io][Serial] [Testpattern: Dynamic PV (default fs)] subPath should verify container cannot write to subpath readonly volumes [Slow] 1m3s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sCSI\sVolumes\s\[Driver\:\spd\.csi\.storage\.gke\.io\]\[Serial\]\s\[Testpattern\:\sDynamic\sPV\s\(default\sfs\)\]\ssubPath\sshould\sverify\scontainer\scannot\swrite\sto\ssubpath\sreadonly\svolumes\s\[Slow\]$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:419
Jan 10 21:12:45.161: waiting for csi driver node registration on: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/drivers/csi.go:463
				
				Click to see stdout/stderrfrom junit_01.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] CSI Volumes [Driver: pd.csi.storage.gke.io][Serial] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow] should concurrently access the single volume from pods on different node 1m3s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sCSI\sVolumes\s\[Driver\:\spd\.csi\.storage\.gke\.io\]\[Serial\]\s\[Testpattern\:\sDynamic\sPV\s\(filesystem\svolmode\)\]\smultiVolume\s\[Slow\]\sshould\sconcurrently\saccess\sthe\ssingle\svolume\sfrom\spods\son\sdifferent\snode$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:318
Jan 10 21:14:37.654: waiting for csi driver node registration on: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/drivers/csi.go:463
				
				Click to see stdout/stderrfrom junit_01.xml

Filter through log files | View test history on testgrid


Test 3h53m

error during ./hack/ginkgo-e2e.sh --ginkgo.focus=\[Serial\]|\[Disruptive\] --ginkgo.skip=\[Flaky\]|\[Feature:.+\] --minStartupPods=8 --report-dir=/workspace/_artifacts --disable-log-dump=true: exit status 1
				from junit_runner.xml

Filter through log files | View test history on testgrid


Show 190 Passed Tests

Show 4665 Skipped Tests